4 - 106 COMMAND REFERENCE
Limitations:
For the PM33x0B CombiScope instruments:
- Input channel 3 (CH3) is not applicable.
- Input channel 4 (CH4) is limited to external trigger view.
Example:
Send
SYSTem:SET? 32 Queries for cursor instrument settings.
Read
<curs_setup> Reads cursor instrument settings.
Send
SYSTem:SET? Queries for all instrument settings.
Read
<settings> Reads all instrument settings.
.
.
Send
SYSTem:SETSP Sends the header plus a space without
message termination (EOI off).
Send
<settings> Sends all instrument settings, plus
message termination (EOI on).
Programming tip:
The number of <settings> bytes can be determined from the second byte of the
returned <settings> information itself. A node is always built up as follows:
<node_nr> <node_length> <first_byte> ... <last_byte>
The second <node_length> byte indicates the number of bytes to follow.
If no <node_nr> was specified the number of bytes must be determined while
reading the <settings>.
Front panel compliance:
The SYSTem:SET? query followed by the SYSTem:SET command gives a
remote possibility to save and recall complete or partial instrument setups.