Earth/Ground Tester
Description of Displays
55
Description of Displays
Table 3. Description of Displays
Function Displays Condition Note
Before
"START"
edw027.eps
Stand by
position to
reduce
power
consump-
tion
Turn rotary
switch or
push
button. All
measured
values
remain
stored
ST
V
edw028.eps
No or
incorrect
measuring
lead
connection
Apart from
voltage
measure-
ment all
measuring
functions
are locked.
LO-BAT
edw029.eps
Battery
voltage too
low
Replace
batteries.
edw030.eps
Beeper on Acoustical
warning if
limit is
exceeded.
Legend: W= displayed flashing