Earth/Ground Tester
Procedure of Measurements
51
Turning the central rotary switch for a short moment deletes the line
compensation again.
R
RA
R
Earth/Ground Resistance 300k
AC
Resistance
300 k
DC Low Resistance 3k
CHANGE
ITEM
SELECT
START
TEST
DISPLAY
MENU
H/C2
S/P2
ES/P1
E/C1
4
POLE
3
POLE
4
POLE
2
POLE
2
POLE
4
POLE
OFF
3
POLE
EARTH / GROUND TESTER
1625
edw026.eps
Figure 20. Compensation of Measuring Lead Resistance
Changing of All Data Settings with Personalized CODE
With this function (FM, UM-Limit, Limit, beeper, ratio, R*, F*) limit- and set
values can be programmed which keeps them memorized even if the instru-
ment is switched ON/OFF. This feature enables the operator to create an in-
strument set-up with customer defined settings according to the specific need.
Settings can only be made in the respective functions: