Users Manual
90
Continuity Testing
TONE RESISTANCE
Continuous Tone
May or may not get tone
No tone
<25
25 to 400
>400
Frequency Measurement
RANGES
MODEL 701 AND 702
COUNTS
1 YEAR 2 YEAR
1 Hz to 109.99 Hz 5 5
110 Hz to 1099.9 Hz 5 5
1.100 kHz to 10.999 kHz 5 5
11 kHz to 50 kHz 5 5
Amplitude range for frequency measurement:
<1 kHz: 110 mV to 300V
1 kHz to 30 kHz: 0.5 to 30V
>30 kHz: 1V to 30V
Input Impedance: 5 M
For frequency measurement less than 109.99 Hz, specification applies for signals with a slew rate greater than 5
volt/millisecond.