Fluke DSP-2000 Manual de usuario Pagina 141

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 196
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 140
Maintenance and Specifications
Maintenance
8
8-3
BATTERY ACCESSBATTERY ACCESS
BATTERY ACCESSBATTERY ACCESS
1
2
BATTERY ACCESSBATTERY ACCESS
3
gc39f.eps
Figure 8-2. Removing the NiCad Battery Pack
Note
The ac adapter/charger will not power the test tool when the battery
pack is removed.
Internal Lithium Backup Battery
A lithium battery maintains the test tool’s memory contents when you remove the
NiCad battery pack. The memory contents maintained are the stored Autotest
reports, all SETUP settings, self-calibration and NVP calibration data, custom
cable configurations, and the report identification information.
The lithium battery lasts about five years if you always keep the main battery
installed. Removing the main battery pack for extended periods shortens the life
of the lithium battery.
Vista de pagina 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 195 196

Comentarios a estos manuales

Sin comentarios