77 Series III
Service Manual
1-6
Table 1-1. Specifications (cont)
Function Range Accuracy
L
3.200 V
32.00 V
320.0 V
1000 V
±(0.3%+1)
±(0.3%+1)
±(0.3%+1)
±(0.4%+1)
m
L
320.0 mV ±(0.3%+1)
K (45 to 500 Hz,
3.2 V range. Other
ranges 45 to 1
kHz)
3.200 V
32.00 V
320.0 V
1000 V
±(2%+2)
±(2%+2)
±(2%+2)
±(2%+2)
e
320.0 Ω
3200 Ω
32.00 kΩ
320.0 kΩ
3.200 MΩ
32.00 MΩ
±(0.5%+3)
±(0.5%+1)
±(0.5%+1)
±(0.5%+1)
±(0.5%+1)
±(2.0%+1)
G R 2.0 V ±(1% typical)
Function Range Accuracy Burden Voltage
(typical)
? (45 Hz to 1 kHz)
32.00 mA,
320.0 mA
10.00 A *
±(2.5%+2)
±(2.5%+2)
6 mV/mA
50 mV/A
A
32.00 mA,
320.0 mA
10.00 A *
±(1.5%+2)
±(1.5%+2)
6 mV/mA
50 mV/A
* 10 A continuous, 20 A for 30 seconds maximum.