Fluke PN 4060712 Manual de usuario

Busca en linea o descarga Manual de usuario para Los termómetros de entorno Fluke PN 4060712. Fluke PN 4060712 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
PN 4060712
April 2012
© 2012 Fluke Corporation. All rights reserved. Printed in China.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
62 MAX/62 MAX +
Infrared Thermometer
Users Manual
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1 - 62 MAX/62 MAX +

PN 4060712 April 2012 © 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All pro

Pagina 2

62 MAX/62 MAX + Users Manual 6 Specifications 62 MAX 62 MAX + Temperature Range -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 120

Pagina 3 - Table of Contents

Infrared Thermometer Specifications 7 Optical Resolution 10:1 (calculated at 90 % energy) 12:1 (calculated at 90 % energy) Display Resolution 0.1

Pagina 4

62 MAX/62 MAX + Users Manual 8 IP Rating IP 54 per IEC 60529 Drop Test 3 meters Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 5

Pagina 5 - How to Contact Fluke

Infrared Thermometer The Product 9 The Product 1 2 gtt01.eps

Pagina 6 - Safety Information

62 MAX/62 MAX + Users Manual 10 3 4Max/Min/Avg/Diff/556 gtt14.eps

Pagina 7 - Safety Information

Infrared Thermometer The Product 11 710 minOFF+= gtt16.eps

Pagina 8

62 MAX/62 MAX + Users Manual 12 911125°F8100ºC32ºF22ºC72ºF1263930 Min gtt15.eps

Pagina 9 - Maintenance

Infrared Thermometer The Product 13 12 1338 mm @300 mm60 mm @600 mm100 mm @900 mm1.5" @12"2.4" @24"4" @36"DS62 MAXD:S

Pagina 10 - Specifications

62 MAX/62 MAX + Users Manual 14 147021 gtt03.eps

Pagina 11 - Specifications

Infrared Thermometer The Product 15 1575°75°225° gtt04.eps

Pagina 12 - Users Manual

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date

Pagina 13 - The Product

62 MAX/62 MAX + Users Manual 16 16 17+- gtt13.eps

Pagina 14

i Table of Contents Title Page Introduction ...

Pagina 15 - The Product

62 MAX/62 MAX + Users Manual ii

Pagina 16

1 Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measuring the amount of in

Pagina 17 - 62 MAX +

62 MAX/62 MAX + Users Manual 2 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To see, pri

Pagina 18

Infrared Thermometer Safety Information 3 • See emissivity information for actual temperatures. Reflective objects result in lower than actual temp

Pagina 19

62 MAX/62 MAX + Users Manual 4 Table 1. Symbols Symbol Meaning Symbol Meaning W Risk of danger. Important information. See Manual. ~ Do not dispose of

Pagina 20

Infrared Thermometer Maintenance 5 Maintenance WCaution To avoid damage to the Product, do not leave the thermometer on or near objects of high temp

Comentarios a estos manuales